FLEXIFIBER® Type BD (Brownian
Diffusion)
The FLEXIFIBER Type BD element uses the Brownian Diffusion mechanism to
achieve collection efficiencies of up to 99.95% or higher on all submicron liquid
particles down to 0.1 microns. Operating pressure drops are normally designed
in the range of 50 to 500 mm (2-20 in) W.G.
An
interesting feature of the FLEXIFIBER Type BD mist eliminator
is that, with submicron particles,
the collection efficiency
actually increases as the gas
flow rate decreases through the bed. Increasing residence time in the fiberbed
optimizes Brownian movement.
Type BD elements are normally cylindrical in shape, and
are available in a wide variety of materials. The Type
BD element packed with carbon fibers is
recommended
if your application contains flourides, a high PH, or is subjected to steam.
This will significantly increase the life expectancy of the element.
How it works
Brownian Diffusion occurs with extremely small droplets that randomly
move from side to side not directly following the path of the gas stream.
Typically,
the
smaller the particle, the greater the Brownian movement.
|